Industry specific power supply
Three phase railway dedicated power board

350-450VAC three-phase four wire input
● Protection type: short circuit/overload/overvoltage
● Constant voltage current limiting mode
FR-4 double-sided board
● Height less than 45mm
Efficiency of over 90%
●MBTF≧100000H
100% full load aging test
Railway design standards
● High lifespan and reliability
● 5-year warranty

详细信息

product model

BLH-ADS-1102D5

output voltage

110VDC

output

2.5A

input characteristics

input voltage

350-450AC 50/60Hz three-phase four-wire

input currenton

1.5A

interiorinput power

280W

power factor

0.6220VAC

productiveness

91%

 

 

 

 

output characteristic

output voltage

±5%

Current accuracy

±5%

power

5W

load regulation

±5%

Input linear adjustment rate

±5%

Boot delay time

Under full load conditions, the start-up time is less than or equal to 3s when the power supply is 100Vac input

 

 

protection feature

overcurrent protection

110%-130%

short-circuit protection

110%

overload protection

110%

Over temperature protection

have

environmental character istics

operating ambient temperature

-20- +60

 

Security features

insulation resistance

50MΩ

withstand voltage

The input to output is 3000VAC 60S, and there is no breakdown

 

design criteria

safety standards

Railway standards

electromagnetic compatibility

Railway standards

 

life span

mean free error time

25Ambient temperature, full load condition, rated voltage input condition, mean time between failures> 50000 hours

Quality assurance service

Two years

Size and weight

product size

280*87*45mm (length * width * height)

Product weight

About 40g

serve

Support customization

Size change (circuit optimization (product upgrade (connection method (other requirements (