model |
SNK-600-5 |
SNK-600-12 |
SNK-600-24 |
SNK-600-36 |
SNK-600-48 |
DC output voltage and current |
5V80A |
12V/50A |
24V25A |
36V 16 .7A |
48V12 .5A |
Ripples and noise |
75mVp-p |
75mVp-p |
100mVp-p |
100mVp-p |
120mVp-p |
Line stability |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
Load stability |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
productiveness |
80% |
84% |
85% |
84% |
87% |
Adjustable range of DC voltage |
±10% |
±10% |
±10% |
±10% |
±10% |
input voltage range |
176-264VAC 47-63HZ-250-370VDC |
||||
dash current |
Cold start current 60A/230V |
||||
overload protection |
Cut output of 105% ~ 130%, and automatically recover |
||||
excess voltage protection |
115%/135% protection mode: turn off the output voltage and restart the output |
||||
Start, rise and hold time |
200ms 50ms 20ms |
||||
resistance to pressure |
Between input and output: 1.5KvAC between input and housing: 1.5Kv between output and housing: 0.5Kv for one minute |
||||
Isolation resistance |
Input and output: input and housing: output and housing: 500VDC/100MΩ |
||||
Working temperature and humidity |
- 10℃~ +60℃ ,20%~90%RH |
||||
safety standards |
Comply with GB4943, UL60950, EN60950 |
||||
EMC standard |
It meets GB9254, EN55022 grade B |
||||
weight |
1 .8Kg |