product model |
LRS- 100-5 |
LRS- 100-12 |
LRS- 100-24 |
LRS- 100-48 |
DC output voltage and current |
5V18A |
12V8.3A |
24V4 .1A |
48V2A |
Ripples and noise |
100mVp-p |
120mVp-p |
150mVp-p |
200mVp-p |
Line stability |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
Load stability |
±1% |
±0.5% |
±0.5% |
±0.5% |
productiveness |
85% |
88% |
90% |
91% |
Adjustable range of DC voltage |
±10% |
±10% |
±10% |
±10% |
input voltage range |
85-264VAC 120-360VAC |
|||
dash current |
50A/230V |
|||
overload protection |
105% --130% cut output, reset: automatic recovery |
|||
excess voltage protection |
115%/145% protection mode: turn off the output voltage and restart the output |
|||
Start, rise and hold time |
500ms 55ms / 230VAC 500ms 30ms / 115VAC |
|||
resistance to pressure |
Input/output: 4KvAC, input and housing: 2KvAC, output and housing: 1.25KvAC for one minute |
|||
Isolation resistance |
Input and output, input and housing, output and housing: 500VDC/100M Ω |
|||
Working temperature and humidity |
- 10℃~ +60℃,20% ~90% RH |
|||
safety standards |
Comply with GB4943, |
|||
EMC standard |
It meets GB9254, EN55022 grade A |
|||
weight |
0 .34Kg |