product model |
LRS-150- 12 |
LRS-150-24 |
LRS-150-36 |
LRS-150-48 |
DC output voltage and current |
12V12.5A |
24V6.5A |
36V4.3A |
48V3.3A |
Ripples and noise |
150mVp-p |
200mVp-p |
200mVp-p |
200mVp-p |
Line stability |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
Load stability |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
productiveness |
87% |
89% |
89% |
90% |
Adjustable range of DC voltage |
±10% |
±10% |
±10% |
±10% |
input voltage range |
85- 132VAC 170-264VAC |
|||
dash current |
Cold start current 60A/230V |
|||
overload protection |
105% --130% cut output, reset: automatic recovery |
|||
excess voltage protection |
115%~ 145% protection mode: turn off the output voltage and restart the output |
|||
Start time, rise and hold time |
500ms 30ms / 230VAC 500ms 30ms / 115VAC at full load |
|||
resistance to pressure |
I/ P-O/ P :3 .75KvAC , l/P-FG :2KvAC , |
|||
Isolation resistance |
I/ P-O/ P, I/ P- FG, O/ P- FG:500VDC/ 100MΩ |
|||
Working temperature and humidity |
- 10℃~ +60℃,20% ~90% RH |
|||
safety standards |
Comply with GB4943, |
|||
EMC standard |
It meets GB9254, EN55022 grade A |
|||
weight |
0 .48Kg |